STARTEX CHEMICAL INC -- XYLENE -- 6810-00-584-4070
===================== Product Identification ===================== Product ID:XYLENE MSDS Date:06/15/1995 FSC:6810 NIIN:00-584-4070 === Responsible Party === Company Name:STARTEX CHEMICAL INC Address:5 HACKBERRY LANE Box:3087 City:CONROE State:TX ZIP:77305 Country:US Info Phone Num:409-539-6244 Emergency Phone Num:409-539-6244/800-424-9300(CHEMTREC) CAGE:0YFV5 === Contractor Identification === Company Name:STARTEX CHEMICAL INC Address:5 HACKBERRY LANE Box:3087 City:CONROE State:TX ZIP:77305 Country:US Phone:409-539-6244 CAGE:0YFV5 ============= Composition/Information on Ingredients ============= Ingred Name:XYLENES (O-,M-,P- ISOMERS) (SARA 313) (CERCLA) CAS:1330-20-7 RTECS #:ZE2100000 Fraction by Wt: 85.0% Other REC Limits:NONE RECOMMENDED OSHA PEL:100 PPM ACGIH TLV:100 PPM/150STEL;9596 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS Ingred Name:ETHYL BENZENE (SARA 313) CAS:100-41-4 RTECS #:DA0700000 Fraction by Wt: 15.0% Other REC Limits:NONE RECOMMENDED OSHA PEL:100 PPM ACGIH TLV:100 PPM/125STEL;9596 EPA Rpt Qty:1000 LBS DOT Rpt Qty:1000 LBS ===================== Hazards Identification ===================== LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER. Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO Health Hazards Acute and Chronic:EYE:IRIT,DOES NOT INJURE EYE TISSUE.SKIN:PREQ/PROL CONTACT MAY IRRIT.LOW ORDER OF TOXICITY.OCCASIONAL BRIEF CONTACT W/LIQ WILL NOT RESULT IN SIGNIFICANT IRRIT UNLESS EVAPORATION IS IMPEDED.INHAL:HI VA P/AEROSOL CONC IRRIT EYES,RESP TRACT,HEAD,DIZZ,ANESTHESIA,DROWS,UNCONSC,OTHER CNS EFFECTS INCLUDE DEATH.LOW ORDER(SUPPL) Effects of Overexposure:EYE IRRIT, SKIN IRRIT, IRRIT RESP TRACT, HEADACHE, DIZZINESS, ANESTHESIA, DROWSINESS, UNCONSC, CNS EFFECTS, DEATH. ASPIRATED INTO LUNGS CAUSE MILD TO SEVERE PULMONARY INJURY. Medical Cond Aggravated by Exposure:SKIN CONTACT MAY AGGRAVATE AN EXISTING DERMATITIS CONDITION. ======================= First Aid Measures ======================= First Aid:EYE:FLUSH W/LG AMTS OF WATER TIL IRRIT SUBSIDES.IRRIT PERSISTS GET MED ATTN.SKIN:FLUSH W/LG AMTS OF WATER.USE SOAP IF AVAILABLE.REMOVE GROSSLY CONTAMIN CLOTH INCLUDING SHOES.INHAL:USING PROPER RESP PR OTECTION IMMED REMOVE AFFECTED VICTIM FROM EXPO.ADMINISTER ART RESP IF BREATH STOP.KEEP @REST.CALL FOR PROMPT MED ATTN.INGEST:DO NOT INDUCE VOMIT.KEEP @REST.GET PROMPT MED ATTN. ===================== Fire Fighting Measures ===================== Flash Point Method:TCC Flash Point:81.0F,27.2C Autoignition Temp:Autoignition Temp Text:932F Lower Limits:1.9 Upper Limits:12.3 Extinguishing Media:USE FOAM OR DRY CHEMICAL TO EXTINGUISH FIRE. Fire Fighting Procedures:COOL FIRE EXPO SURFACES/PROT PEOPLE.DISPERSE VAP FROM LEAK/SPILL W/WATERSPRAY.RESP/EYE PROT REQUIRED FOR FIREFIGHT PERSON.AVOID SPRAY WATER INTO CNTNR-BOILOVER. Unusual Fire/Explosion Hazard:FLAMM LIQ,CAN RELEASE VAP THAT FORM FLAMM MIXTURES @TEMP @/>FLASH PT.STATIC DISCHAR MATL CAN ACCUMULATE STATIC CHARGES-CAN CAUSE INCENDIARY ELEC DISCHAR.(SUPPL) ================== Accidental Release Measures ================== Spill Release Procedures:ELIMINATE IGN SOURCES.STOP LEAK/SPILL W/O RISK.IMPLEMENT CLEANUP PROCEDURES.KEEP PUBLIC WAY.ADIVSE AUTHORITIES.IF SUBJ TO CERCLA REPORTING NOTIFY NAT RESP CNTR.PREVENT ENTER SEWERS/WATERCOURSE/LOW ARE AS.CONTAIN W/SAND/EARTH.DON'T USE COMBUST (SUPPLE) Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER. ====================== Handling and Storage ====================== Handling and Storage Precautions:EMPTIED CNTNRS MAY BE HAZ.SINCE EMPTIED CNTNRS RETAIN RESIDUE(LIQ/VAP/SOILD)ALL HAZ PRECAUT GIVEN MUST BE OBSERVED. Other Precautions:WARNING!SUDDEN RELEASE OF HOT ORG CHEM VAP/MIST FROM PROCESS EQPMT OPERATING @ELEVATED TEMP/PRESSURE/SUDDEN INGRESS OF AIR INTO VAC EPQMT MAY RESULT IN IGN W/O PRESENCE OF OBVIOUS IGN SOURCES.ANY USE OF PROD IN ELEVATED TEMP PROCESSES(SUPP) ============= Exposure Controls/Personal Protection ============= Respiratory Protection:WHERE CONC IN AIR MAY EXCEED LIMITS GIVEN THIS SECTION & ENGINEERING WORK PRACTICE OR OTHER MEANS OF EXPO REDUCTION ARE NOT ADEQUATE NIOSH/MSHA APPROVED RESPIRATORS MAY BE NECESSARY TO PREVENT OVEREXP O BY INHAL. Ventilation:LOC EXHAU VENTI RECOMMENDED TO CONTROL PROCESS EMISSIONS NEAR SOURCE.LAB SPL IN HOOD.MECH VENTI CONFINE SPACE.EXPLO-PROF Protective Gloves:CHEM-RESISTANT GLOVES. Eye Protection:SAFETY GLASSE W/SIDE SHIELDS Other Protective Equipment:LONG SLEEVES. Work Hygienic Practices:LAUNDER CONTAMIN CLOTH/SHOES BEF REUSE. Supplemental Safety and Health FIRE/EXPLO HAZ:LIQ VOLATILE,INVISIBLE VAP,LOW AREA SETTLE.HEALTH HAZ:TOXICITY. SPILL:MATL(SAWDUST).RECOVE BY PUMP/SUITABLE ABSORBENT.CONSULT EXPERT ON DISPO.WATER SPILL:IF ALLOWED SINK/SUITABLE DISPER SANTS USED IN NON-CONFINED WATERS. OTHER PRECAUT:SHOULD BE WELL EVALUATED TO ESTABLISH & MAINTAIN SAFE OPER CONDITION. ================== Physical/Chemical Properties ================== HCC:F4 Boiling Pt:B.P. Text:283F,139C Melt/Freeze Pt:M.P/F.P Text:-31F,-35C Decomp Temp:Decomp Text:NP Vapor Pres:14 @100F Vapor Density:NP Spec Gravity:0.87 @60F pH:NP Viscosity:0.7CST @77F Evaporation Rate & Reference:0.8, (N-BUTYL ACETATE=1) Solubility in Water:0.02, NELGIGIBLE. Appearance and Odor:NONE SPECIFIED BY MANUFACTURER. Percent Volatiles by Volume:NP Corrosion Rate:NP ================= Stability and Reactivity Data ================= Stability Indicator/Materials to Avoid:YES STRONG OXIDIZING AGENTS,CONC NITRIC & SULPHURIC ACIDS, HALOGEN, AND MOLTEN SULPHUR. Stability Condition to Avoid:TEMPERATURE ABOVE AMBIENT. Hazardous Decomposition Products:TOXIC GASES WILL FORM UPON COMBUSTION. FUMES, SMOKE, CARBON MONOXIDE. ==================== Disposal Considerations ==================== Waste Disposal Methods:EMPTY DR SHOULD BE COMPLETELY DRAINED/PROPERLY BUNGED/PROMPTLY RETURNED TO DR RECONDITINER/PROPERLY DISPO OF. Disclaimer (provided with this information by the compiling agencies): This information is formulated for use by elements of the Department of Defense. The United States of America in no manner whatsoever, expressly or implied, warrants this information to be accurate and disclaims all liability for its use. Any person utilizing this document should seek competent professional advice to verify and assume responsibility for the suitability of this information to their particular situation.