KRYLON/SPRAYON INDUS PRODS,SHWERWIN-WILLIAMS -- 1301 CRYSTAL CLEAR ACRYLIC -- 8010-00-990-7289
=====================  Product Identification  =====================

Product ID:1301 CRYSTAL CLEAR ACRYLIC
MSDS Date:09/01/1996
FSC:8010
NIIN:00-990-7289
=== Responsible Party ===
Company Name:KRYLON/SPRAYON INDUS PRODS,SHWERWIN-WILLIAMS
Address:31500 SOLON ROAD
City:SOLON
State:OH
ZIP:44139
Country:US
Info Phone Num:800-777-2966/800-247-3266
Emergency Phone Num:216-566-2917
CAGE:MO454
=== Contractor Identification ===
Company Name:KRYLON/SPRAYON INDUS PRODS,SHWERWIN-WILLIAMS
Address:31500 SOLON ROAD
Box:City:SOLON
State:OH
ZIP:44139
Country:US
Phone:800-777-2966/800-247-3266
CAGE:MO454
Company Name:NASCO INTL INC., NASCO DIV
Address:901 JANESVILL AVE
Box:City:FORT ATKINSON
State:WI
ZIP:53538-0901
Country:US
Phone:920-563-2446
CAGE:33089
Company Name:SHERWIN-WILLIAMS DIVERSIFIED BRANDS, INC.
Address:26300 FARGO AVENUE
Box:City:BEDFORD HEIGHTS
State:OH
ZIP:44146
Country:US
Phone:216-292-7400 OR 216-595-8634
CAGE:09800

=============  Composition/Information on Ingredients  =============

Ingred Name:PROPANE
CAS:74-98-6
RTECS #:TX2275000
Fraction by Wt: 15%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:ASPHYXIANT; 9596

Ingred Name:BUTANE
CAS:106-97-8
RTECS #:EJ4200000
Fraction by Wt: 15%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:800 PPM
ACGIH TLV:800 PPM; 9596

Ingred Name:LIGHT ALIPHATIC HYDROCARBON
CAS:64742-89-8
Fraction by Wt: 6%
Other REC Limits:NONE RECOMMENDED

Ingred Name:ETHYL BENZENE (SARA 313)
CAS:100-41-4
RTECS #:DA0700000
Fraction by Wt: 4%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/125STEL;9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:XYLENES (O-,M-,P- ISOMERS) (SARA 313) (CERCLA)
CAS:1330-20-7
RTECS #:ZE2100000
Fraction by Wt: 23%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:100 PPM
ACGIH TLV:100 PPM/150STEL;9596
EPA Rpt Qty:1000 LBS
DOT Rpt Qty:1000 LBS

Ingred Name:MED. AROMATIC HYDROCARBONS
CAS:64742-94-5
RTECS #:WF3100000
Fraction by Wt: 2%
Other REC Limits:NONE RECOMMENDED

Ingred Name:ACETONE (SARA 313) (CERCLA)
CAS:67-64-1
RTECS #:AL3150000
Fraction by Wt: 26%
Other REC Limits:NONE RECOMMENDED
OSHA PEL:1000 PPM
ACGIH TLV:750PPM/1000STEL;9596
EPA Rpt Qty:5000 LBS
DOT Rpt Qty:5000 LBS

=====================  Hazards Identification  =====================

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES  Skin:YES  Ingestion:NO
Reports of Carcinogenicity:NTP:NO    IARC:NO	OSHA:NO
Health Hazards Acute and Chronic:EXPO MAY BE BY INHAL &/OR SKIN/EYE
    COTNACT DEPENDING ON CONDITIONS OF USE.TO MIN EXPO FOLLOW
    RECOMMENDATIONS FOR PROPER USE/VENTI/PPE.IRRIT EYE/SKIN/RESP
    SYS.MAY CAUSE NERV SYS DEPRESS.EXTREME OVEREXP O MAY RESULT IN
    UNCONSC,POSSIBLY DEATH.
Explanation of Carcinogenicity:PER MSDS:CHROMATES LISTED BY
    IARC/NTP.STUDIES HAVE ASSOC EXPO TO CR VI CMPDS W/INCR RISK OF
    RESPIRATORY CANC.CA PROP 65.
Effects of Overexposure:HEAD,DIZZ,NAU,LOSS OF COORDINATION INDICATIONS
    OF EXCESSIVE EXPO TO VAP/SPRAY MISTS.REDNESS,ITCHING OR BURNIG SENS
    MAY INDICATE EYE/EXCESSIVE SKIN EXPO.PROL OVEREXPO TO SLVT INGREDS
    MAY CAUSE ADVERSE  EFFECTS TO
    LIVER/URINARY/BLOOD-FORMING,CARDIOVASCULAR/REPRODUCTIVE
    SYST.REPORTS HAVE ASSOC REP/PROL OVEREXPO TO (SUPPLE)
Medical Cond Aggravated by Exposure:NONE GENERALLY RECOGNIZED.

=======================  First Aid Measures  =======================

First Aid:INHAL:IF AFFECTED REMOVE FROM EXPO.RESTORE BREATH.KEEP
    WARM/QUIET.SKIN:WASH AREA THOROUGHLY W/SOAP/WATER.REMOVE CONTAM
    CLOTH.EYE:FLUSH W/LG AMTS OF WATER FOR 15MINS.GET MED
    ATTN.INGEST:NEVER GIVE ANYT HING BY MOUTH IF UNCOSNC.DONT INDUCE
    VOMITING.GIVE CONSC PATIENT SEVERAL GLASSES OF WATER.SEEK MED ATTN.

=====================  Fire Fighting Measures  =====================

Flash Point Method:PMCC
Flash Point:<0F,<-18C
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:0.9
Upper Limits:13.1
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM.
Fire Fighting Procedures:FULLL PROT EQPMT INLCUDE SCBA SHOULD BE
    USED.H2OSPRAY MAY BE INEFFECT.IF H2O USED FOG NOZZ PREFER.H2O MAY
    BE USED TO COOL CLSD CNTNR TO PREVENT PRESSURE (SUPPL)
Unusual Fire/Explosion Hazard:ISOLATE FRM HEAT/ELECT EQPMT/SPARK/OPN
    FLAME.CLSD CNTNR MAY EXPLO WHEN EXPO TO EXTREME HEAT.APPLICATION OT
    HOT SURF REQUIRES SPEC PRECAUT.DURING EMERG (SUPPLE)

==================  Accidental Release Measures  ==================

Spill Release Procedures:REMOVE ALL SOURCES OF IGNITION.VENTILATE &
    REMOVE W/INERT ABSORBENT.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

======================	Handling and Storage  ======================

Handling and Storage Precautions:USE ONLY W/ADEQU VENTI.AVOID BREATH
    VAP/SPRAY MIST.AVOID SKIN/EYE CONTACT.CONTENTS EXTREMELY FLAMM.KEEP
    AWAY FRM HEAT/SPARK/OPN FLAME.
Other Precautions:VAP ACCUMULATE READILY,MAY IGN EXPLO.DONT
    SMOKE,EXTING ALL IGN SOURCES,TURN OFF STOVES,ETC.BOND/GROUND-SEE
    NFPA.COATINGS MAY CONTAIN MATLS CLASS AS NUISANCE PARTICULATES
    WHICH MAY BE PRESENT @HAZ LEVE LS ONLY DURING SAND/ABRADE OF DRIED
    FILM

=============  Exposure Controls/Personal Protection  =============

Respiratory Protection:PERSONAL EXPO CANT BE CONTROL BEL APPLIC LIMITS
    BY VENTI WEAR PROPERLY FIT ORG VAP/PARTICULATE RESP NIOSH/MSAH
    APPROV FOR PROT AGAINST INGREDS.WHEN
    SAND/WIREBRUSH/ABRADE/BURN/WELD DRIED FILM WEAR PART ICULATE RESP
    NIOSH/MSHA APPROV
Ventilation:LOC EXHAU PREFER.GEN EXHAU ACCEPTABLE IF EXPO TO INGREDS
    MAINTAIN BEL APPLIC EXP LIMITS.REF:OSHA 1910.94,107,108.
Protective Gloves:NONE REQUIRE FOR NORMAL APPLICATION
Eye Protection:SAF SPECTACLES W/UNPERFORATE SIDESHIELDS
Other Protective Equipment:FOR LONG/REP SKIN CONTACT WEAR CHEM RESIST
    GLOVES.
Work Hygienic Practices:WASH CONTAM CLOTH BEF REUSE.WASH HANDS AFT
    USING.INTENTIONAL MISUSE BY DELIVERATELY CONCEN/INHAL CONTENTS
    HARMFUL/FATAL.
Supplemental Safety and Health
FIREFIGHT:BUILDUP & POSSIBLE AUTOIGN/EXPLO WHEN EXPO TO EXTREME HEAT.
    FIRE/EXPLO:CONDITIONS OVEREXPO TO DECOMPO PRODS MAY CAUSE HEALTH
    HAZ.SYMPTOMSMAY NOT BE IMMED APPARENT.OBTAIN MED ATTN. SIGN/SYMPT
    OMS:SOLVTS W/PERM BRAIN/NERV SYST DMG. DISPO:REGS REGARDING
    POLLUTION.

==================  Physical/Chemical Properties  ==================

HCC:F1
Boiling Pt:<-17.8C, 0.F
Vapor Pres:NA
Vapor Density:>AIR
Spec Gravity:NA
pH:NP
VOC Grams/Liter:3.94
Viscosity:NP
Evaporation Rate & Reference:FASTER THAN ETHER
Solubility in Water:NA
Appearance and Odor:CRYSTAL CLEAR ACRYLIC COAT/VARNISH
Percent Volatiles by Volume:NP
Corrosion Rate:NP

=================  Stability and Reactivity Data  =================

Stability Indicator/Materials to Avoid:YES
NONE KNOWN
Stability Condition to Avoid:NONE SPECIFIED BY MANUFACTURER.
Hazardous Decomposition Products:BY FIRE:CARBON DIOXIDE, CARBON
    MONOXIDE.

====================  Disposal Considerations  ====================

Waste Disposal Methods:CONTAIN CHEMS SUBJ TO REPORT REQMTS OF SARA SEC
    313/40CFR372.65C.WASTE FRM PROD MAY BE HAZ AS DEF UNDER RCRA
    40CFR261.WASTE MUST BE TESTED FOR IGNIT TO DETERMINE APPLI EPA HAZ
    WASTE#.DONT INCINERATE.D EPRESSURIZE CNTNR.DISPO OF IAW
    FED/STATE/LOC(SUPP)

 Disclaimer (provided with this information by the compiling agencies):
 This information is formulated for use by elements of the Department
 of Defense.  The United States of America in no manner whatsoever,
 expressly or implied, warrants this information to be accurate and
 disclaims all liability for its use.  Any person utilizing this
 document should seek competent professional advice to verify and
 assume responsibility for the suitability of this information to their
 particular situation.